1.1 Installation
Cooling
The MRD 3187B is cooled via forced induction through the front of the unit and exhausted
through the vents on either side. The MRD 3187B is equipped with a temperature controlled
status indicator. If the temperature in the inside of the unit exceeds 70° C the red “Error”
LED will illuminate and a description of the error will appear in the “Error List.”
Rack Information
The MRD 3187B is intended to be mounted in a standard 19” rack. It occupies 1U of rack
space and the connections are all on the rear of the unit.
Rack Installation
To install the MRD 3187B into a rack use the
following steps:
1. Determine the desired position in the rack for the
MRD 3187B making sure that the air intake on
the front of the unit and the exhausts on the sides
of the unit will not be obstructed.
2. Insert the rack mount clips into place over the
mounting holes in the rack.
3. Slide the MRD 3187B into position in the rack.
4. Secure the MRD 3187B to the rack by installing
the four supplied screws through the front
mounting holes and tightening.
Power Connection
Using the proper power connections is vital to the safe operation of the MRD 3187B. Only
use the supplied 3-prong power connector or one with equal specifications. NEVER tamper
with or remove the 3
rd
prong grounding pin. This could cause damage to the MRD 3187B,
personnel, or property.